Water Cooled Medium Frequency Induction Heater
video
Water Cooled Medium Frequency Induction Heater

Water Cooled Medium Frequency Induction Heater

Water cooled medium frequency induction heater Medium frequency water-cooled heater, using water circulation heat dissipation method for heating, has the advantages of fast heat dissipation and fast heating rate. The main features are as follows: 1. Precise control Medium frequency induction...

Shandong Weiterui Industrial Technology Co., Ltd. is one of the leading manufacturers and suppliers of water cooled medium frequency induction heater in China. Welcome to buy high quality bearing heaters made in China here from our factory. Please be free to enjoy our discount price and good service.

 

Water-Cooled Medium Frequency Induction Heater

Application-matched induction heating with circulating-water cooling.

The Water-Cooled Medium Frequency Induction Heater provides 15–160 kW power options for metal heating processes. Select the power supply, induction coil and cooling system together to suit the workpiece and production cycle.

15–160 kW   /   4–20 kHz   /   Three-phase 380 V   /   Water cooling

Coil-connected and split-unit configurations are shown in the supplied product range. Handheld heating arrangements can be assessed where the coil and cable configuration suit the task.

What Is a Water-Cooled Medium Frequency Induction Heater?

An induction coil creates an alternating magnetic field. This field induces electrical currents in a conductive metal workpiece, generating heat within the metal. Coil design and the selected operating frequency influence how the heat is distributed.

In this series, the listed output frequency is 4–20 kHz, selected according to the workpiece heating requirements. Circulating water removes heat from the connected equipment and coil circuit as specified for the configuration.

Cooling water supports equipment operation. It is not the source of the workpiece heating. The Water-Cooled Medium Frequency Induction Heater requires a suitable cooling-water circuit before heating begins.

Applications and Workpieces

Process Selection considerations
Shrink-fit mounting Assess suitable metal rings, sleeves, gears or couplings by their material, dimensions, fit and required temperature.
Thermal dismounting Assess accessible rings or sleeves using the assembly drawing, removal direction and heating requirements.
Process preheating Match the coil, power and temperature monitoring to the required heating area and production procedure.
Higher-temperature heating or melting The source table includes cooling recommendations for heating above 300°C or melting. Confirm the coil, tooling and cooling arrangement for the specific process.

These are application types to assess, not a universal capability for every workpiece. Confirm material, mass, geometry and process temperature before selecting a configuration.

Product Features

Circulating-water cooling

A connected cooling circuit removes heat from the equipment and the water-cooled heating arrangement. The circuit needs the specified water quality, flow, pressure and inlet temperature.

Adjustable heating settings

The illustrated control panels include power adjustment, timing controls, operating indications and a digital display. Confirm the controls included with the selected power configuration.

Coil and split-unit options

Choose the coil connection and unit layout to suit the heating position. Where available, a handheld arrangement and matched cable length can help reach workpieces that are difficult to position beside a fixed machine.

Continuous-operation capability

The source specification lists a 100% duty cycle and 24-hour continuous operation. This requires the approved load, cooling conditions and operating limits for the final configuration.

Temperature control to suit the process

Specify the required target temperature, measurement method and control accuracy. Confirm whether a sensor and closed-loop temperature control are included in the quotation.

How to Select the Right Power

1. Define the workpiece

Send the metal type, drawing, dimensions, mass and heating area. For ring heating, include bore diameter, outside diameter, width and the shaft arrangement where relevant.

2. Define the heating cycle

State the starting temperature, target temperature, required heating time and parts per hour. Power cannot be selected reliably from workpiece diameter alone.

3. Match the coil and frequency

The coil geometry and its coupling to the workpiece affect heating performance. WTR will assess the coil and a suitable output frequency within the listed 4–20 kHz range.

4. Check the electrical and cooling supplies

Confirm the site voltage and available electrical capacity. Select a cooling system for the power level, process temperature, ambient conditions and continuous workload.

5. Confirm the layout and controls

State whether you need coil-connected, split-unit or handheld operation, the working distance, and the required timing or temperature-control functions.

Power options: 15, 25, 35, 45, 70, 90, 110 and 160 kW. Lower-power configurations may suit smaller heating loads. Higher-power configurations can be considered when the workpiece or target cycle needs more heating capacity. Validate the selected configuration against the actual process.

Series Technical Specifications

Parameter Listed specification
Product name Water-Cooled Medium Frequency Induction Heater
Power options 15 / 25 / 35 / 45 / 70 / 90 / 110 / 160 kW
Input supply Three-phase 380 V ±20%
Output oscillation frequency 4–20 kHz, according to workpiece heating requirements
Cooling method Circulating-water cooling
Listed duty cycle 100%; 24-hour continuous operation under specified operating conditions
Output voltage, 15 kW 70–520 V
Output voltage, 25–160 kW 70–550 V
Power option Source-listed current range (A) Source-listed weight values (kg)
15 kW 3–22 23 + 30
25 kW 5–36 28 + 30
35 kW 5–53 43 + 50
45 kW 5–68 50 + 55
70 kW 5–107 60 + 55
90 kW 5–137 70 + 60
110 kW 5–170 80 + 65
160 kW 5–240 80 + 70

The source labels the current range as "output". It is not presented here as the mains input current and must not be used to size the supply circuit. Ask for the final input-current rating and connection specification.

Weight values are retained as the two figures listed in the source. The source does not clearly identify the two assemblies. Final weight and scope depend on the selected configuration.

Reference Dimensions

Power option Main unit dimensions (mm) Additional unit dimensions (mm)
15 kW 520 × 290 × 520 540 × 280 × 520
25 kW 520 × 290 × 520 540 × 280 × 520
35 kW 520 × 290 × 500 580 × 280 × 530
45 kW 650 × 350 × 560 560 × 290 × 520
70 kW 650 × 350 × 560 560 × 290 × 520
90 kW 810 × 410 × 880 570 × 410 × 520
110 kW 810 × 410 × 880 570 × 410 × 520
160 kW 850 × 800 × 500 550 × 410 × 520

These dimensions are reference values from the supplied table. The source identifies a main unit and an additional unit but does not fully define the additional assembly. Cable interfaces and configuration changes can affect dimensions. Confirm the final layout drawing before installation.

Cooling System Selection

Provide a suitable circulating-water system, such as an application-matched chiller or an approved plant cooling-water circuit. Confirm whether the cooling equipment is included or supplied separately.

Heater power Source chiller recommendation for above-300°C heating / melting
15 kW 2P
25 kW 3P
35 kW 3P
45 kW 3P
70 kW 5P
90 kW 6P
110 kW 8P
160 kW 15–20P

The source uses the supplier sizing designation "P". These values are preliminary recommendations, not measured cooling capacities in kW. Confirm the chiller's actual cooling capacity, operating conditions and compatibility before purchase.

Confirm water connections for the selected configuration

The supplied pictures and source table show different connection arrangements. The number of water ports, hose diameters and circuit layout vary by configuration. Use the final connection drawing and water-flow requirements.

Before heating

Establish cooling-water circulation and verify the required flow, pressure and inlet temperature. Check for leaks and use the operating manual for startup and shutdown.

During maintenance

Inspect hoses, fittings and the cooling circuit. Maintain water quality and service the cooling equipment according to the supplied instructions.

Water Cooling and Air Cooling

Item Water-cooled configuration Air-cooled configuration
Cooling arrangement Requires an approved circulating-water circuit. Uses airflow for equipment cooling.
Installation Needs water connections and suitable cooling equipment. Check airflow, ventilation and installation clearance.
Maintenance Inspect water quality, flow, hoses and leakage. Inspect fans, filters and ventilation paths as applicable.
Selection Assess cooling capacity against the actual load and process. Assess the specific equipment rating against the actual load and ambient conditions.

Choose the complete heating system for the process. The cooling method alone does not establish the heating speed, efficiency or suitable duty cycle.

Frequently Asked Questions

Does water cooling mean that no cooling water is required?

No. The Water-Cooled Medium Frequency Induction Heater requires circulating cooling water. Confirm the cooling equipment, water conditions and connection arrangement for the selected configuration.

How do I choose between 15 kW and 160 kW?

Provide the workpiece material, mass, drawing, target temperature and required heating time. WTR can assess a suitable power option together with the coil and cooling system.

Can it operate continuously?

The supplied specification lists a 100% duty cycle and 24-hour operation. Confirm the permitted load and required cooling conditions for the final system.

Is automatic temperature control included?

Specify temperature measurement and control requirements when ordering. Do not assume that timing or power adjustment alone provides closed-loop temperature control.

Can the heating coil be customized?

Request a coil matched to the workpiece shape and heating area. Confirm the connection, cooling requirements and operating frequency with the selected power supply.

Is a handheld heating arrangement available?

The supplied product material illustrates a handheld arrangement. Confirm availability, cable length, coil design and the applicable power configuration before ordering.

Can it be used for melting?

The source includes reference cooling recommendations for melting. A suitable coil, tooling and process assessment are required. Send the metal type, quantity and target cycle for confirmation.

What electrical installation information should I request?

Request the final input rating, phase and frequency requirements, protection and connection specification, earthing requirements and installation drawing. Supply wiring must be selected for the actual installation.

Are the high-frequency and ultra-high-frequency products shown in the related-products image part of this series?

They are separate product options. This page covers the Water-Cooled Medium Frequency Induction Heater and its listed 4–20 kHz range. Confirm a different frequency range through its own specification.

What is needed for a quotation?

Send the workpiece drawing and material, mass, heating task, target temperature, cycle time, site supply, cooling conditions and desired configuration.

Request a Heating Configuration

Send WTR your workpiece drawing, material, weight and required heating cycle.

Include the available voltage, cooling conditions and preferred unit layout. WTR can assess the power option, coil, operating frequency, cooling system and control configuration for your application.

 

Hot Tags: water cooled medium frequency induction heater, China, factory, suppliers, manufacturers, price, buy discount, made in China, Intermediate Frequency Induction Heater Series

Send Inquiry