Products
80KVA Industrial Heaters
video
80KVA Industrial Heaters

80KVA Industrial Heaters

1.Large induction heater is mainly used to heat metal ring-shaped parts,such as large bearings,gears and so on.
2.It features fast heating speed and high efficiency.
3.This model supports customization and can also be fitted with a crane for picking up and placing parts,which is more convenient and quicker.
Welcome to enquiry!

Shandong Weiterui Industrial Technology Co., Ltd. is one of the leading manufacturers and suppliers of 80kva industrial heaters in China. Welcome to buy high quality bearing heaters made in China here from our factory. Please be free to enjoy our discount price and good service.

 

80KVA Industrial Heaters
We are manufacturer of bearing heaters

High quality and good service manufacturer, 1-on-1 service and the warranty of 12 months,so you can worry free after-sales service.

  • 5K +
    Completed Projects
    5k+ Cooperation Cases
  • 20 +
    Our Technical Expert
    Customised solutions
Large Induction Heater WTR HOR 65KVA
Large Induction Heater WTR HOR 65KVA Large Induction Heater WTR HOR 35KVA

Introduction to Low Frequency Bearing Heater
Our induction heater's heating rod is made of 0.35mm military grade silicon steel sheet by die-casting, all metal material (except for insulation board), with heating efficiency three times that of other brand heater,and also supports customization.

WTR induction heaters can heat large metal circular workpieces.

We have cooperated with many enterprises in the wind power industry, steel industry, and more than 100 Fortune 500 companies,ensuring our strength and high product quality.

 

Industrial Induction Heater details 

a979dc86250dd38f4736a4d6067b272

Bearing Heater Induction Parameters

MODEL POWER MINIMUM
INNER DIAMETER
MAXIMUM
OUTER DIAMETER
MAXIMUM
WIDTH
TEMPERATURE
CONTROL
TIME
CONTROL
MACHINE
WEIGHT/SIZE
WTR-HOR160-4 16KVA 50mm 600mm standard:240mm
customized:350mm
K-type sensor;300℃ 0-9999s 370KG/1700*600*920mm
WTR-HOR250-4 25KVA 80mm 800mm 250mm K-type sensor:300℃ 0-9999s 300KG/1400*600*914mm
WTR-HOR350-4 35KVA 90mm 900mm 300mm K-type sensor:300℃ 0-9999s 380KG/2210*600*914mm
WTR-HOR500-4 50KVA 120mm 1000mm 300mm K-type sensor:300℃ 0-9999s 1800*700*1100mm
WTR-HOR650-4 65KVA 160mm 1200mm 300mm K-type sensor:300℃ 0-9999s 600KG/2300*900*1041mm
WTR-HOR800-4 80KVA 210mm 1400mm 300mm K-type sensor:300℃ 0-9999s 2116*777*1155mm
 
FAQ

Q: Does the bearing heater emit high radiation to the human body?

A:The bearing heater does generate electromagnetic radiation during operation, but the magnitude and degree of its impact on human body radiation need to be considered from multiple aspects.
1.Radiation level
Frequency comparison: The frequency of the bearing heater is 50Hz, which is the same as the frequency of our household electric lights and much lower than the frequency range of high-frequency radiation (such as medium wave and short wave radiation of 100-1000Hz). Therefore, from a frequency perspective, its radiation level is relatively small.
Radiation intensity: Although the bearing heater generates radiation, its radiation intensity is much lower than that of a mobile phone. Under normal usage, the direct impact of this radiation on the human body can be basically ignored.
2.Radiation impact
Human health: Long term exposure to electromagnetic waves may have certain impacts on human health, such as headaches, fatigue, insomnia, etc. However, due to the low radiation level of bearing heaters and the fact that they are usually not directly exposed to radiation sources for a long time in daily use, their direct impact on human health is limited.
Equipment interference: Electromagnetic waves may also cause interference to surrounding electrical equipment, leading to equipment damage or failure. To reduce this interference, appropriate preventive measures can be taken, such as placing the bearing heater at a safe distance.
3.Preventive measure
Safe distance: When using a bearing heater, a certain safe distance should be maintained to reduce the risk of direct exposure to radiation sources.
Protective equipment: Using protective equipment such as work clothes and gloves with electromagnetic wave shielding can reduce the impact of radiation on the human body to a certain extent.
Regular maintenance: Regularly maintain and upkeep the heater to ensure its normal operation and reduce the generation and leakage of electromagnetic waves.
4.Conclusion
In summary, the radiation dose of bearing heaters to the human body is relatively small, and they usually do not pose direct and significant harm to human health in daily use. However, in order to further reduce the impact of radiation, it is recommended to take appropriate preventive measures, such as maintaining a safe distance, using protective equipment, and regularly maintaining the heater. At the same time, we should remain vigilant and follow relevant safety usage guidelines for any equipment that may generate radiation.

Hot Tags: 80KVA Industrial Heaters, China, factory, suppliers, manufacturers, price, buy discount, made in China, inspection induction heater, magnetic induction heater, production induction heater, assembly induction heater, grinding induction heater, welding induction heater

Send Inquiry